GET V1 stability/measurements
Gets the details of all Stability Measurements defined in the EMS.
Authentication
This endpoint requires the api-username and api-usertoken headers for authentication.
Request Information
Example Request
To get all Stability Measurements, make the following API call: GET /stability/measurements
Request Detail
This endpoint requires the api-username and
api-usertoken headers to be present. If these headers are not present, a 401 (Unauthorized)
response will be returned.
Response Information
HTTP Status Codes
| Status Code | Meaning |
|---|---|
| 200 (OK) | The request has completed successfully. The Stability Measurements will be contained in the response body (see below). |
| 401 (Unauthorized) | The user has not been authorised. Please ensure that the client provides the api-username and api-usertoken headers. |
Response Detail
An empty collection means that there are no Stability Measurements defined.
Response Body Formats
application/json, text/json
Sample:
[
{
"ID": 1,
"Name": "rheometry",
"Methods": [
{
"ID": 7,
"Name": "FabConStressProfile",
"Description": "Increasing Shear rate 1-100 then decrease 100-1",
"Fields": []
}
],
"DispenseSettings": [
{
"ID": 8,
"Name": "Std Viscosity Dispense (1 mm/s)"
}
]
},
{
"ID": 2,
"Name": "pH",
"Methods": [
{
"ID": 9,
"Name": "pH_Only",
"Description": "pH measurement",
"Fields": []
},
{
"ID": 10,
"Name": "pH (System Defined)",
"Description": "System defined pH method to allow manual entry of pH",
"Fields": [
{
"ID": 11,
"Name": "pH",
"Description": "Manual entry of pH",
"HasLimits": true
}
]
}
],
"DispenseSettings": [
{
"ID": 12,
"Name": "Dispense Setting"
}
]
},
{
"ID": 3,
"Name": "Particle Size",
"Methods": [
{
"ID": 13,
"Name": "Malvern 1",
"Description": "Malvern 1 Method Description",
"Fields": []
}
],
"DispenseSettings": [
{
"ID": 14,
"Name": "Opaque"
}
]
},
{
"ID": 4,
"Name": "Refractive Index",
"Methods": [
{
"ID": 15,
"Name": "Refractive Index Analysis",
"Description": "RI analysis",
"Fields": []
}
],
"DispenseSettings": [
{
"ID": 16,
"Name": "Standard"
}
]
},
{
"ID": 5,
"Name": "Colour",
"Methods": [
{
"ID": 17,
"Name": "Colour Method",
"Description": "Colour Method description",
"Fields": []
}
],
"DispenseSettings": [
{
"ID": 18,
"Name": "Test Setting"
},
{
"ID": 19,
"Name": "Standard"
}
]
},
{
"ID": 6,
"Name": "Observation",
"Methods": [
{
"ID": 20,
"Name": "Shampoo",
"Description": "Observational measures for Shampoo",
"Fields": [
{
"ID": 21,
"Name": "Odour Intensity",
"Description": "",
"HasLimits": false
}
]
}
],
"DispenseSettings": []
}
]
application/xml, text/xml
Sample:
<ArrayOfMeasurement xmlns:i="http://www.w3.org/2001/XMLSchema-instance" xmlns="http://schemas.datacontract.org/2004/07/Unilever.Urdps.Hts.EmsApi.EntityRepresentations.Stability.V1">
<Measurement>
<DispenseSettings>
<MeasurementDispenseSetting>
<ID>8</ID>
<Name>Std Viscosity Dispense (1 mm/s)</Name>
</MeasurementDispenseSetting>
</DispenseSettings>
<ID>1</ID>
<Methods>
<MeasurementMethod>
<Description>Increasing Shear rate 1-100 then decrease 100-1</Description>
<Fields />
<ID>7</ID>
<Name>FabConStressProfile</Name>
</MeasurementMethod>
</Methods>
<Name>rheometry</Name>
</Measurement>
<Measurement>
<DispenseSettings>
<MeasurementDispenseSetting>
<ID>12</ID>
<Name>Dispense Setting</Name>
</MeasurementDispenseSetting>
</DispenseSettings>
<ID>2</ID>
<Methods>
<MeasurementMethod>
<Description>pH measurement</Description>
<Fields />
<ID>9</ID>
<Name>pH_Only</Name>
</MeasurementMethod>
<MeasurementMethod>
<Description>System defined pH method to allow manual entry of pH</Description>
<Fields>
<MethodField>
<Description>Manual entry of pH</Description>
<HasLimits>true</HasLimits>
<ID>11</ID>
<Name>pH</Name>
</MethodField>
</Fields>
<ID>10</ID>
<Name>pH (System Defined)</Name>
</MeasurementMethod>
</Methods>
<Name>pH</Name>
</Measurement>
<Measurement>
<DispenseSettings>
<MeasurementDispenseSetting>
<ID>14</ID>
<Name>Opaque</Name>
</MeasurementDispenseSetting>
</DispenseSettings>
<ID>3</ID>
<Methods>
<MeasurementMethod>
<Description>Malvern 1 Method Description</Description>
<Fields />
<ID>13</ID>
<Name>Malvern 1</Name>
</MeasurementMethod>
</Methods>
<Name>Particle Size</Name>
</Measurement>
<Measurement>
<DispenseSettings>
<MeasurementDispenseSetting>
<ID>16</ID>
<Name>Standard</Name>
</MeasurementDispenseSetting>
</DispenseSettings>
<ID>4</ID>
<Methods>
<MeasurementMethod>
<Description>RI analysis</Description>
<Fields />
<ID>15</ID>
<Name>Refractive Index Analysis</Name>
</MeasurementMethod>
</Methods>
<Name>Refractive Index</Name>
</Measurement>
<Measurement>
<DispenseSettings>
<MeasurementDispenseSetting>
<ID>18</ID>
<Name>Test Setting</Name>
</MeasurementDispenseSetting>
<MeasurementDispenseSetting>
<ID>19</ID>
<Name>Standard</Name>
</MeasurementDispenseSetting>
</DispenseSettings>
<ID>5</ID>
<Methods>
<MeasurementMethod>
<Description>Colour Method description</Description>
<Fields />
<ID>17</ID>
<Name>Colour Method</Name>
</MeasurementMethod>
</Methods>
<Name>Colour</Name>
</Measurement>
<Measurement>
<DispenseSettings />
<ID>6</ID>
<Methods>
<MeasurementMethod>
<Description>Observational measures for Shampoo</Description>
<Fields>
<MethodField>
<Description></Description>
<HasLimits>false</HasLimits>
<ID>21</ID>
<Name>Odour Intensity</Name>
</MethodField>
</Fields>
<ID>20</ID>
<Name>Shampoo</Name>
</MeasurementMethod>
</Methods>
<Name>Observation</Name>
</Measurement>
</ArrayOfMeasurement>